MiniTest 70FN

Variants

Description

For measuring any non-magnetic coatings (paint, enamels, chrome, etc.) on ferro-magnetic bases (e.g. constructional steel, car bodies, etc. )or measuring any non-magnetic coatings (paint, enamels, etc.) on ferro-magnetic bases (e. g. constructional steel, car bodies, etc.) as well as for measuring insulating coatings (e.g. paint, enamels, anodic films, etc.) on non-ferrous metal bases (e. g. aluminium, copper, brass, etc. )

Overview

Application

Non-destructive measurement of:

  • non-magnetic coatings such as paint, enamel, chrome and zinc on ferromagnetic bases
  • insulating coatings such as paint, anodic coatings on non-ferrous metal bases

Performance features

  • Dual sensor for automatic identification of the substrate (FN model). According to the substrate, it adjusts to the appropriate measuring principle: magnetic induction or eddy currents principle.
  • Quick statistics mode to calculate the number of readings, average, standard deviation and min., max. value
  • lightweight: 80 grams only

Scope of delivery

  • Steel and aluminium test plates
  • Calibration foils
  • Operating instructions
  • Gauge tether
  • Storage case

Technical details

Property Value
Measuring range
N: 0 mm - 2.5 mm/ 100 mils
F: 0 mm - 3 mm/ 120 mils
Measuring principle
magnetic-induction/eddy currents
Signal processing
Sensor integrated 32-bit signal processing (SIDSP®)
Accuracy
± (1.5 μm + 3% of reading) with 1-point calibration ± (0.06 mils + 3% of reading) with 1-point calibration ± (1.5 μm + 2% of reading) with 2-point calibration2 ± (0.06 mils + 2% of reading) with 2-point calibration2
according to DIN 55350 Part 13

according to DIN 55350 Part 13
Repeatability
± (1 μm + 1% of reading) / ± (0.04 mils + 1% of reading)
according to DIN 55350 Part 13according to DIN 55350 Part 13
Low range resolution
0.5 µm
0.02 mils
Minimum curvature radius convex
5 mm
0.2 ''
Minimum curvature radius concave
40 mm
1.60 ''
Minimum substrate thickness
F: 0.5 mm - 0.02 ''
N: 0.04 mm - 0.0016 ''
Measuring units
metric/imperial switchable
Calibration
standard, 1-point and 2-point calibration
Statistics
n, x, s, Min, Max
Operating temperature
-10 °C - 60 °C
14 °F - 140 °F
Storing temperature
-20 °C - 70 °C
-4 °F - 158 °F
Power supply
1x AA (Mignon)-battery
International standards
DIN EN ISO 1461, 2064, 2178, 2360, 2808, 3882, ASTM B 244, B 499, D7091, E 376
Dimensions
approx. 157 mm length, Ø 27 mm; 5.2" length, Ø 1.06"
Weight
~ 80 grams, 2.8 oz
incl. batteryincl. battery

Downloads

Brochure MiniTest 70 Brochure MiniTest 70 Brochure MiniTest 70, 2 pages, A4, English
B35 N engl B35 N engl Operating instructions

Events / Tradeshows

  • Metal Tech Exhibition

    Malaysia / 21st ... 25th May 2013

  • Forum Labo & Biotech 2013

    France / 4th ... 7th Jun 2013

  • REW 2013

    Turkey / 13th ... 16th Jun 2013

Need technical advice?

You are working with a manufacturing process requiring special measuring methods and tools? It will be our pleasure to advise you on possible solutions!
Please feel free to contact us on:

Phone: +49 221 75204-0
Fax: +49 221 75204-67
Mail: info(at)elektrophysik.com

or using the -> contact form